Reference Settings for the supported Instruments
Error Codes
Error Message Description
Possible Solut
ions
E1009
Check for prob
e polarity
Sync eld is re
versed
If the probe is
reversed,
the sync eld pattern is
reversed and hence the
test fails
xxx
Settings for the supported Instruments
This section gives a list of default oscilloscope settings that the application uses for supported instruments.
The recommended voltage probe for single-ended signals are the P6245 or P6243 or TDP1500 or TDP3500
or TAP1500 probes and for differential signals is the P6248 or P6330 probe. The next table shows the
oscilloscope settings for Low Speed and Full Speed signals for the supported instruments.
Upstream Setups for Low Speed signals
Ch. Vertical SetupPos. Scale
Offset Coupling
Horizont
al
SetupRecord Main
Trigger length scale
pos.
Trigger SetupTrigger Logic Pattern
Threshold Trigger type function limit
mode
Repeat
State
Ch1(D-
)
01V0
DC
5000 2.00
E-07s
74%
Logic AND >100 ns 800 mV Nor-
mal
Off
Ch2(D+
)
01V0
DC N/A N/A N/A N/A N/A N/A
800 mV
N/A N/A
Ch3Qu
al-
ify
01V0
DC N/A N/A N/A N/A N/A N/A
2.7 V
N/A N/A
xxx
Upstream Setups for Full Speed Signals
You c
an test the Full Speed devices at Tier 6. This testing is also known as legacy testing.
When Full Speed and Low Speed device are High Speed capable, the application uses the signal rate limits
of F
ull Speed/Low Speed devices which a re not High Speed capable t o determine PASS or FAIL.
Ch. Ver
tical SetupPos. Scale
Offset Coupling
Horizontal
Set
upRecord Main
Trigger length scale
pos.
Tri
gger SetupTrigger Logic Pattern
Threshold Trigger type function
limit mode
Re-
peat
State
Ch1(D-)
01V0
DC
5000 25
E-9s
83%
Logic AND >100 ns 800 mV Nor-
mal
Off
Ch2(D+)
01V0
DC N/A N/A N/A N/A N/A N/A
800 mV
N/A N/A
Ch3
Q
ual-
ify
01V0
DC N/A N/A N/A N/A N/A N/A
2.7 V
N/A N/A
xxx
162 TDSUSB2 Universal Serial Bus Measurements Package

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Tektronix TDSUSB2 and is the answer not in the manual?

Tektronix TDSUSB2 Specifications

General IconGeneral
BrandTektronix
ModelTDSUSB2
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals