Command Descriptions
2–140
TDS Family Oscilloscope Programmer Manual
<Space>
<NR1>
HEADer
ON
OFF
?
ON or <NR1>  0 sets the Response Header Enable State to true. This causes the
digitizing oscilloscope to include headers on applicable query responses. You can
then use the query response as a command.
OFF or <NR1> = 0 sets the Response Header Enable State to false. This causes the
digitizing oscilloscope to omit headers on query responses, so that only the
argument is returned.
HEADER OFF
causes the digitizing oscilloscope to omit headers from query responses.
HEADER?
might return the value 1, showing that the Response Header Enable State is true.
HORizontal? (Query Only)
Returns all settings for the horizontal commands. The commands HORizon-
tal:MAIn:SCAle, HORizontal:MAIn:SECdiv, HORizontal:SCAle, and HORi-
zontal:SECdiv are equivalent so HORizontal:MAIn:SCAle is the only value that
is returned.
Horizontal
HORizontal?
HORizontal
?
HORIZONTAL?
might return the string :HORIZONTAL:MODE MAIN;RECORDLENGTH 500;
POSITION 5.0E+0;TRIGGER:POSITION 50;:HORIZONTAL:MAIN:SCALE
1.0E-6;:HORIZONTAL:DELAY:MODE RUNSAFTER;SCALE 1.0E-6;TIME:
16.0E-9
Arguments
Examples
Group
Syntax
Examples

Table of Contents