Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
31
3. CODES – 1. USERS – 01. USER – 3. NAME
Programming of the User 01 Name
The engineer can enter a new name for User 01 at this address. The name has to be up 16 symbols
– letters (small and capital), digits and special symbols, including spaces.
The letters can be entered directly by the digit buttons. The cursor moves automatically to the right
after choosing of letter or digit, or may be moved manually by the arrows. To enter a digit, press the
respective button and hold it for 2-3 seconds. See also item 2.8. Entering text for LCD Keyboard.
Confirm the new user name with ENTER button.
Default name: User 01
3. CODES – 1. USERS – 01. USER – 4. PROXY
Assigning rights for operation with proximity card for User code 01
The engineer assigns rights to the proximity card for operation (arm, disarm) with User code 01. The
settings at this address include operation with a built-in in a keyboard proxy reader only.
According the settings at the address the user code can perform disarming and/ or arming the
system.
The arming options are set as a combination of options 2 and 3.
To enable an option press the digit button corresponding to its number. The next pressing of the
same button will deselect it.
The enabled option is indicated as digit on the LCD display or lighting on zone number on the LED
display. For LED 8/ 16A keyboards the set option is indicated with a lighting on digit button.
The set options are confirmed with ENTER button.
The following options are assigned at this address:
Authorization for the user code to Disarm the site with a proximity card.
DISARM ENABLE (1) – The user code can disarm the site with a proximity
card.
DISARM DISABLE () – The user code cannot disarm the site with a
proximity card.
2. Proxy card
ARMING options
The options 2 and 3 are assigned in a certain combination to set the
arming mode when using a proximity card:
3. Proxy card
ARMING options
1013>CD1_PROXY
[1*3_____]
User code 01 can disarm the associated to it areas and to realize Full Arming when using a
proximity card for system management.
Default settings: DISARM ENABLE; SLEEP ARM