Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
32
U1 T.SLOT
ADDRESS
1014
OPERATION
114+01
TEXT MENU
3. CODES 1. USERS 01. USER 5.TIMESLOT
Programming of time slot for User code 01
An access code timeslot is set.
The valid timeslot numbers are from 1 to 8. If the selected access code is not to be restricted by a
timeslot, enter 0.
Use the digit buttons to enter the timeslot number. The entered number is confirmed with ENTER.
For programming of timeslots, see for details Menu. 5 Timeslot Programming.
Default settings: 0
User codes form 02 to 08/ 32/ 64 are programmed in an analogical way.
The rights of User codes set at addresses 1хх0 (110 + хх), where “xx” is a user number from 02 to 08/ 32/ 64, can be
enabled or disabled according the system settings:
Uxx
OPTIONS
ADDRESS
1xx0
OPERATION
110+xx
TEXT MENU
3. CODES 1. USERS xx. USER 1. OPTIONS
User xx Operation rights
The following options are assigned for the User xx Code:
1. DISARM
DISARMING the site:
DISARM ENABLE (1) the user code has right to disarm the site
DISARM DISABLE () the user code has not right to disarm the site
2. PART ARM
Partial arming
Partial arming STAY or SLEEP type:
PART ARM ENABLE (2) the user code has right to realize partial arming
STAY or SLEEP type
PART ARM DISABLE () the user code has not right to realize partial arming
STAY or SLEEP type
3. BYPASS
Zone
Bypassing
Bypassing zones in the site:
BYPASS ENABLE (3) the user code has right to bypass zones
BYPASS DISABLE () the user code has not right to bypass zones
4. PROGRAM
Programming change own code, reviewing the memory log, enabling/
disabling the “chime” sound signalization, zone bypassing:
PROGRAM ENABLE (4) the user code can realize programming
PROGRAM DISABLE () - the user code cannot realize programming
5. N.A
6. N.A
7. N.A
8. MANAGER
MANAGER in
the system
Manager in the system can program user codes and rights in the system,
reviewing the memory log, zone bypassing:
MANAGER ENABLE (8) the code has Manager rights
MANAGER DISABLE () the code has not Manager rights
When the option 8. MANAGER is enabled, it is obligatory to enable and option 4. PROGRAM!
To disable/ enable all user operation rights press button “0” – the button alternatively switches over
all enabled / all disabled state.
Default settings:
User codes
ECLIPSE 8
ECLIPSE 16
ECLIPSE 32
01
1, 2, 3, 4
1, 2, 3, 4
1, 2, 3, 4, 8
02-08
1, 2
1, 2
1, 2
09-32
33-64