Eclipse 8/ 16/ 32 Series - Engineer Programming Manual
32
3. CODES – 1. USERS – 01. USER – 5.TIMESLOT
Programming of time slot for User code 01
An access code timeslot is set.
The valid timeslot numbers are from 1 to 8. If the selected access code is not to be restricted by a
timeslot, enter 0.
Use the digit buttons to enter the timeslot number. The entered number is confirmed with ENTER.
For programming of timeslots, see for details Menu. 5 Timeslot Programming.
Default settings: 0
User codes form 02 to 08/ 32/ 64 are programmed in an analogical way.
The rights of User codes set at addresses 1хх0 (110 + хх), where “xx” is a user number from 02 to 08/ 32/ 64, can be
enabled or disabled according the system settings:
3. CODES – 1. USERS – xx. USER – 1. OPTIONS
User xx Operation rights
The following options are assigned for the User xx Code:
DISARMING the site:
DISARM ENABLE (1) – the user code has right to disarm the site
DISARM DISABLE () – the user code has not right to disarm the site
2. PART ARM
Partial arming
Partial arming STAY or SLEEP type:
PART ARM ENABLE (2) – the user code has right to realize partial arming
STAY or SLEEP type
PART ARM DISABLE () – the user code has not right to realize partial arming
STAY or SLEEP type
Bypassing zones in the site:
BYPASS ENABLE (3) – the user code has right to bypass zones
BYPASS DISABLE () – the user code has not right to bypass zones
Programming – change own code, reviewing the memory log, enabling/
disabling the “chime” sound signalization, zone bypassing:
PROGRAM ENABLE (4) – the user code can realize programming
PROGRAM DISABLE () - the user code cannot realize programming
8. MANAGER
MANAGER in
the system
Manager in the system – can program user codes and rights in the system,
reviewing the memory log, zone bypassing:
MANAGER ENABLE (8) – the code has Manager rights
MANAGER DISABLE () – the code has not Manager rights
When the option 8. MANAGER is enabled, it is obligatory to enable and option 4. PROGRAM!
To disable/ enable all user operation rights press button “0” – the button alternatively switches over
all enabled / all disabled state.
Default settings: