1.
Test button: Push to check the capacity of the battery pack.
2.
Capacity indicator: LEDs that show the capacity of the battery pack.
3.
Clip: Locks/unlocks the battery pack in the Wireless Unit.
Battery Charging and Handling
Charge the Confidea battery pack immediately on receipt.
Recharge the battery pack immediately when the remaining capacity drops below 20%. This
is when the LED flashes red on the battery pack.
Empty battery packs must be charged within 30 days.
Do not leave an empty battery pack in a delegate unit.
Best practice for maximizing the lithium ion battery life is to keep the batteries in the charging
tray between uses and provide proper ventilation.
The lifetime of a battery pack can be severely affected if it is completely drained. If a
delegate unit is put in storage or is not being used for a while, remove the battery pack and
place it in the charger.
Store the Confidea FLEX G4 battery pack correctly: temperature between 0°C and 60°C
and with a relative humidity between 5% and 75%.
Capacity Indicator
The indicator is a five-segment LED. The first LED (LED1) is red and indicates a low capacity battery. The
higher the charge, the more LEDs that light up.
LED on Remaining charge
LED 1 (red) 0-20%
LED 2 (orange) 20-40%
LED 3 (orange) 40-60%
LED 4 (green) 60-80%
LED 5 (green) 80-100%
BATTERY PACK 31