52
5.15.1 Monitoring
I/O monitoring starts after enabling I/O element and setting up I/O parameters as it is
shown below:
Figure 48 I/O settings
5.15.2 Event Generating
Events happen when the value of enabled I/O intersects thresholds (enter, exit or on both)
predefined by High and Low level thresholds. Table below defines all available values of I/O
settings.
Setting
Value
Priority
low, high
High level
maximum threshold
Low level
minimum threshold
Generate event
on interval enter, on interval exit, on both enter and exit
Average constant
1 – 2
32
(4 Bytes)
Figure 49 Digital Input event generation example
5.15.3 Hysteresis
Figure 50 Hysteresis parameter configuration
I/O elements can generate events according to hysteresis algorithm. If I/O event operand
“Hysteresis” is selected, events will be generated as it is shown in the illustration below (I/O
speed is taken as I/O value example):