63
8.2.5 Static Navigation (ID=1003)
When static navigation is enabled, FMA110 filters out GPS jumps, when it is not moving.
When it is disabled, it does not make any changes to collected GPS data.
Goes with (depends on)
parameters
8.2.6 Ignition source (ID=1004)
Device can operate and change its working mode according to motion detection source:
Power Voltage (value 0), Digital Input 1 (value 1), movement (value 2).
Goes with (depends on)
parameters
Ignition detection
(ID=1920)
Ignition detection timeout
(ID=1921)
Power Voltage High Level
(ID=1005)
Power Voltage Low Level
(ID=1006)
8.2.7 Ignition detection (ID=1920)
If ignition source is Power voltage device can operate in 2 different ignition detection
regimes - Manual (value 0) and Auto (value 1). In manual regime power voltage high and power
voltage low levels need to be set. In auto regime device automatically detects system voltage (6V,
12V or 24V) and detects ignition according default voltage ranges.
Goes with (depends on)
parameters
Ignition source
(ID=1004)
Ignition detection timeout
(ID=1921)
8.2.8 Ignition detection timeout (ID=1921)
When ignition source is selected as Power Voltage and Ignition detection is set as auto,
ignition timeout need to be set.
Goes with (depends on)
parameters
Ignition source
(ID=1004)
Ignition detection
(ID=1920)