85
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
-2147483647
2147483647
0
I/O#1 property parameter (ID=1300)
I/O#1 priority (ID=1301)
I/O#1 High level (ID=1302)
I/O# logic operand (ID=1304)
I/O#1 Averaging length (ID=1305)
S32
8.7.5 I/O#1 logic operand (ID=1304)
Parameter defines when event is sent: 0 – on range exit, 1 – on range entrance, 2 – both,
3 – monitoring, 4 – hysteresis, 5 – on changes.
Minimal
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
4
3
I/O#1 property parameter
(ID=1300)
I/O#1 priority (ID=1301)
I/O#1 High level (ID=1302)
I/O# Low level (ID=1303)
I/O#1 Averaging length (ID=1305)
S8
8.7.6 I/O#1 averaging length (ID=1305)
Parameter defines I/O property sample length to average. If no averaging needed default
value is 1.
Minimum
value
Maximum
value
Recommended
value
Goes with (depends on)
parameters
Value
type
0
2592000
1
I/O#1 property parameter
(ID=1300)
I/O#1 priority (ID=1301)
I/O#1 High level (ID=1302)
I/O# Low level (ID=1303)
I/O#1 Logic operand (ID=1304)
S32
Other I/O property elements can be configured in same logic. All I/O element parameters
are listed in the next table.