Device Management
- 81 -
8.5.3 Application Scenarios
Networking requirements
The switch shall be connected to the SNMP administrator through Ethernet, the IP
address of switch is 192.168.0.1/24, and the IP address of SNMP administrator is
192.168.0.212/24.
SNMP administrator monitors and manages the switch through SNMP v1 or SNMP v2c,
and the switch can aggressively report to the SNMP administrator in case a fault or error
takes place.
Networking assumption
Read only key is “Jack”, and Read & Write key is “Jack 123”.
Networking diagram
Configuration procedures
I. Configure the switch
Procedure 1: Enable the SNMP function of switch, and configure the SNMP community
string.
1. Log in to the Web network management of the switch, and then go to Device
Management > SNMP configuration page;
2. SNMP: Click the drop-down box, and select the Enable
3. Community String: Read only group name is to be changed to “Jack”, and Read & Write
community string is to be changed to “Jack 123”.
4. Click OK