7.21 Electrical System
The electrical systems in PT machines are equipped with fuses that help to pro-
tect the electrical components from damage. They are found in the fuse panel
enclosure which is located on the left side of the engine compartment.
In the event of an electrical malfunction, check the fuse panel. Remove the fuse
related to the component that is not working properly and inspect it. If it appears
damaged in any way, replace it.
7 MAINTENANCE
78
40
40
50
20
30
20
60
50
5
5
10
5
10
30
15
10
10
10
5
10
5
20 A. RELAY
#12077866
35 A . RE LAY
# 12177234
35 A . RELAY
# 12177234
10
5
PWR RELAY A
PWR RELAY B
GLOW PLUG
STARTER
PWR OUTLET
MAIN
MAIN
20 A. RELAY
#12077866
20 A. RELAY
#12077866
20 A. RELAY
#12077866
L . AUX HYD R. AUX HYD
SAFETY
STARTER
LIGHTS MAIN PWR B
IGNITION
SAFETY RLY
INJ. PUMP
AUXILIARY
BKUP ALM
ALT
HRN-
LT
-SW
HEATER
DOME
BEACON
ALT. DIODE
AUX HYD
WIPER
MICRO SW
ELECTRICAL PANEL
A/C
MICRO
40 A . RELAY
# 87417B
GLOW PLUG
40 A . RELAY
# 87417B
AUX LDR 1
40 A . RE LAY
# 87417B
AUX LDR
2
40 A . RE LAY
# 87417B
AUX LDR 3
40 A . RELAY
# 87417B
AUX LDR
4
40 A . RELAY
# 87417B
MAIN PWR A
LIGHTS
FLOAT MAG
2010511
20