TESTO 320 basic Specifications

General IconGeneral
Product TypeCombustion Analyzer
Dimensions240 x 85 x 65 mm
Operating Temperature-5 to +45 °C
Storage Temperature-20 to +50 °C
Battery TypeRechargeable Li-ion battery
Measuring range O20 to 21 vol. %
Measuring range CO0 to 4000 ppm
Accuracy O2±0.2 vol. %
Resolution CO1 ppm
Resolution flue gas temperature0.1 °C
Resolution draught0.01 hPa
Resolution differential pressure0.01 hPa
Protection classIP40
DisplayGraphic display
Measuring range Temperature+600 °C
Accuracy CO±20 ppm (0 to 400 ppm) ±5% of reading (401 to 2000 ppm)
Accuracy Temperature±0.5 °C
Measurement parametersO2, CO, temperature
Measurement ranges draught-9.99 to +9.99 hPa
Accuracy draught±0.03 hPa
Resolution O20.1 %
Operating conditions-5 to +45 °C
Storage conditions-20 to +50 °C
InterfacesUSB, Infrared
SoftwareEasyHeat

Summary

Safety and the environment

About this document

Explains manual usage, safety instructions, and warning symbols.

Ensure safety

Provides crucial instructions and warnings for safe operation and maintenance.

Protecting the environment

Details proper disposal of batteries and the product at its end-of-life.

Specifications

Use

Lists the intended applications and tasks for the testo 320 basic.

Technical data

Contains detailed technical information about the instrument.

Examinations and licenses

Lists product certifications and compliance standards.

Measurement ranges and resolution

Details measuring parameters, their ranges, and resolution.

Accuracy and response time

Provides accuracy specifications and response times for measurement parameters.

Other instrument data

Lists general instrument specifications like temperature, power, and weight.

Product description

Measuring instrument

Describes the main instrument unit.

Front view

Identifies main components on the front of the instrument.

Keypad

Explains the function of each button on the instrument's keypad.

Display

Describes the status bar, info field, selection, and function display areas.

Instrument connections

Details probe socket, gas outlet, and USB socket locations.

Condensate outlet and interfaces

Identifies the infrared interface and condensate outlet.

Rear view

Identifies strap attachment, condensate trap, magnetic holder, and service lid.

Components

Shows internal components like battery, pump, and sensor slots.

Compact flue gas probe

Identifies the parts of the flue gas probe.

First steps

Commissioning

Basic steps before initial use, including battery charging.

Getting to know the product

Familiarization with the instrument's basic functions.

Mains operation

Explains how to power the instrument using the mains adapter.

Connecting probes

Instructions on how to connect flue gas probes and adapters.

Switching on

Describes turning the instrument on and initial setup.

Calling up the function

Explains how to navigate menus and select functions.

Entering values

Details how to input data, units, or characters via the interface.

Printing/saving data

Explains how to print or save measurement data.

Saving data to the clipboard (temporary memory)

Describes using the clipboard for temporary data storage.

Confirming an error message

Explains how to acknowledge and deal with error messages.

Switching off

Details the procedure for turning the instrument off.

Measurement records

Explains how to call up, display, and print measurement records.

Instrument diagnosis

Covers displaying instrument errors, sensor status, and information.

Using the product

Performing settings

Guides through the configuration and adjustment of instrument settings.

Assigning the right function key

How to assign functions to the instrument's right function key.

Instrument settings

Configuration options for the instrument's operation.

Measurement view

How to configure displayed parameters, units, and layout.

Alarm limits

How to set and manage audible and visual alarm signals.

Date / time

Instructions for setting the instrument's date and time.

Power Options

Configuration of automatic shutdown and display brightness.

Display brightness

How to adjust the intensity of the display illumination.

Printer

Configuration of printout headers, footers, and printer activation.

Language

How to select and activate the menu language.

Country version

Explains how country version affects calculations and languages.

Password protection

Details how to activate, deactivate, and change the password.

Sensor settings

Configuration options for the instrument's sensors.

O2 reference

How to set the reference value for the O2 sensor.

Recalibration/adjustment

Procedures for recalibrating and adjusting sensors.

Fuels

How to select the fuel type for accurate measurements.

Measuring

Detailed instructions for performing various measurements.

Preparing for measurement

Steps to prepare the instrument and system before measurement.

Testing for leaks

Procedure to ensure the measurement system is leak-tight.

Zeroing phases

Explains gas and draught/pressure zeroing procedures.

Using the modular flue gas probe

Instructions on checking and aligning the flue gas probe.

Measurement view

How to set up the display for parameters and units.

Setting the fuel

Reiteration of selecting the correct fuel before measurements.

Flue gas

Steps to perform a flue gas measurement and available options.

Draught measurement

Procedure for performing draught measurements.

Smoke number/HCT

How to determine smoke number and heat carrier temperature.

Pressure

Instructions for performing pressure measurements.

Differential temperature

Procedure for performing differential temperature measurements.

Ambient CO

Instructions for measuring ambient carbon monoxide.

Transferring data

Methods for transferring measurement data from the instrument.

Report printer

How to transmit data to a Testo report printer.

PC

How to transfer data to a PC using a USB connection.

Maintaining the product

Cleaning the measuring instrument

Instructions for cleaning the instrument's housing.

Replacing the rechargeable battery

Step-by-step guide for replacing the instrument's battery.

Charging the battery

Instructions for charging the instrument's rechargeable battery.

Replacing sensors

Step-by-step guide for replacing sensors.

Recalibrating/adjusting sensors

Refers to the recalibration section for sensor adjustment.

Compact flue gas probe

Maintenance procedures for the compact flue gas probe.

Cleaning the probe shaft

Instructions for cleaning the probe shaft.

Replacing the thermocouple

Step-by-step guide for replacing the thermocouple.

Checking the particle filter

How to check the particle filter for contamination.

Replacing the particle filter

Step-by-step guide for replacing the particle filter.

Condensate container

Instructions for draining and maintaining the condensate container.

Tips and assistance

Questions and answers

Common issues and their solutions, troubleshooting guide.

Accessories and spare parts

Lists available accessories and spare parts with article numbers.

Updating the instrument software

Guide on installing firmware updates for the instrument.

Related product manuals