9.1 EMERGENCY SHUTDOWN
• Switch on the brake on your TESUP Charge Controller to position 1.
The wind turbine is now short-circuited via the TESUP Charge Controller.
• Cover the blades or take off and store the blades in a dry place.
9.2 TEMPORARY SHUTDOWN
• Switch on the brake on your TESUP Charge Controller to position 1.
The wind turbine is now short-circuited via the TESUP Charge Controller.
• This type of shutdown can occur during the stormy weather when the wind speed is higher
than 27 m/s. If this is the case, cover your blades.
9.3 AUTOMATIC BRAKE
Automatic brake function on the TESUP Charge Controller securely slows down and controls
the wind turbine’s fast acceleration. To activate the auto-brake function;
• Use your charge controller in battery mode.
• Adjust your maximum voltage via the potentiometer button.
• Your wind turbine will brake when it reaches the max voltage value set by the
potentiometer.
NOTE: There is no max voltage limitation in inverter mode.
27TESUP Electronics Ltd. All rights reserved. ©2023 | www.tesup.com
9. Shutting Down
Wind Turbine
HERA WIND PRO USER MANUAL
WARNING: Always shut down the wind turbine system prior to all
maintenance work. Stopping the turbine should be done in low
wind speed conditions.