Programming the Alarm System Premier Series Master User Guide
46 INS177
User Options 1
This menu defines which options are available to the user when their code is entered.
This menu is not available to all users.
Press
*
to scroll through the options and press
$
to select them or use keys
!
-
5
(‘Letter’ = option IS selected, ‘Star’ = option is NOT selected).
The following options are available:
A - Arming
Areas assigned to the selected user can be armed.
D - Disarming
Areas assigned to the selected user can be disarmed.
O - Omitting
Zones assigned to the same areas as the selected user can be omitted, providing that
they have the ‘Omit’ attribute assigned to them.
R - Eng. Reset (Engineers only)
Areas programmed as ‘Engineer Reset’ can be reset after an Alarm has occurred.
a - Local Arming (not on Premier 24)
The User can only arm areas that the keypad is assigned to.
d - Local Disarm (not on Premier 24)
The User can only disarm areas that the keypad is assigned to, or areas that are in entry or
alarm (provided that the code has that area assigned to it).
Y - Auto ‘YES’
After a code is entered, pressing
#
to confirm the next action is not required.
F - Disarm First (not on Premier 24)
If an area is armed and the user enters their code, the ‘Disarm’ option is displayed first.
The following attributes are only available on the Premier 24.
!"
Some of the following options may not always be selectable or de-selectable.
T - Lock TAG = PGM2
The Users TAG is disabled whenever PGM2 is active.
C - Lock Code = PGM3
The Users code is disabled whenever PGM3 is active (default = during the Entry mode).
U - Lock User = PGM4
The Users TAG and Code is disabled whenever PGM4 is active (default = Control Timer 4).
O - Open/Close
The selected user will report open (disarm) and close (arm) events to an Alarm Receiving
Centre every time they arm or disarm.