Table of Contents
2 INS 034-9
Table of Contents
Section Page
1 Programming Summary 4
1.1 Programming Menu 4
1.1.1 Factory Settings 5
2 Installation 6
2.1 Introduction to the Control Panel 6
2.2 Testing the Control Panel (Pre-Installation) 6
2.3 Mounting the Control Panel 6
2.4 Wiring the Control Panel 7
2.4.1
Veritas
PCB Layouts 8
2.4.2 Wiring the External Sounder and Strobe 9
2.4.3 Magnetic Contacts and Panic Buttons 12
2.4.4 Powered Detectors 13
2.4.5 Extension Speaker(s) 14
2.4.6 Internal Siren(s) 14
2.4.7 Global System Tamper 14
2.5 Commissioning the System (Initial Power Up) 15
2.6 Servicing the System 16
2.7 Trouble Shooting 17
2.7.1 No Power to the Unit (Mains Only) 17
2.7.2 No Power to the Unit (Battery Only) 17
2.7.3 No Power to the Unit (Mains & Battery) 17
2.7.4 Unit Does Not Accept Code 17
2.7.5 Unit Will Not Set and Bleeps 10 Times 17
2.7.6 Unit Will Not Set and Bleeps 9 Times 18
2.7.7 Unit Will Not Set and Bleeps Between 1 & 8 Times 18
2.7.8 Unit Goes Into False Alarm 18
2.7.9 Unit Makes No Sound 18
2.7.10 System Operates but Remote Keypad Makes No Sound 19
2.7.11 The External Sounder or Strobe Does Not Work 19
2.7.12 The Panic Button Does Not Work 19
2.7.13 The Service Timers Cannot Be Programmed 19
3 Programming 20
3.1 The Programming Menu 20
3.2 Programming the Miscellaneous Selections 20
3.2.1 Miscellaneous Selections Zero
!!
20
3.2.2 Miscellaneous Selections One
!"
21
3.2.3 Miscellaneous Selections Two
!#
22
3.2.4 Miscellaneous Selections Three
!$
22
3.2.5 Engineer Reset 23
3.2.6 Push To Set 24
3.3 Programming the Number of Alarm Activations
!%
24
3.4 Testing the Sounders, Strobe and SW+
!&
24
3.5 Walk Testing
!'
,
"(
25
3.6 Re-Loading the Factory Settings
!)
26
3.7 Programming the Switched Positive Output
!*
26
3.8 Configuring the Remote Keypad(s)
!(
27
3.9 Zone Types 27
3.9.1 Description of Zone Types 27
3.9.2 Programming the Zone Type 29
3.10 Changing Zone Types when Part Setting 30
3.10.1 Programming the Zones that will Change to Entry/Exit
#"
31
3.10.2 Programming the Zones that will Change to Inhibited Entry
##
31
3.10.3 Programming the Zones that will Change to Guard
#$
31

Table of Contents

Other manuals for Texecom Veritas R8

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texecom Veritas R8 and is the answer not in the manual?

Texecom Veritas R8 Specifications

General IconGeneral
Zones8
Tamper ProtectionYes
Power Supply230V AC
KeypadLED keypad
Part Set Suites2
User Codes6 user codes
Event LogNo