Textron Bunton EC Hydro Midsize 930024 - Hydraulic Reservoir Maintenance

Textron Bunton EC Hydro Midsize 930024
78 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
GB-17
EC
Hydro
Midsize
MAINTENANCE
HYDRAULIC RESERVOIR
CHECK, DRAIN AND FILL
Check level every 100 hours or when a leak has
occurred. To check level: Remove reservoir cap. Add
10W30 oil until the oil level reaches the bottom of the
filler tube. Do not overfill.
EVERY 500 HOURS:
Change hydraulic oil and filter. Remove plug D to
drain reservoir. Remove and replace filter. Filter is
located on front of tank at G. Reinstall plug and fill
with 10W30 oil to the bottom of the filler tube F.