EasyManuals Logo

Textron Cessna 172R User Manual

Textron Cessna 172R
500 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #78 background imageLoading...
Page #78 background image
SECTION
3
EMERGENCY
PROCEDURES
CESSNA
MODEL
172R
ELECTRICAL
FIRE
IN
FLIGHT
1.
Master
Switch
--
OFF.
2.
Vents,
Cabin
Air,
Heat
-
CLOSED.
3.
Fire
Extinguisher
~
ACTIVATE
(if
available).
4.
Avionics
Master
Switch
--
OFF.
5.
All
Other
Switches
(except
ignition
switch)
--
OFF.
A
WARNING
AFTER
DISCHARGING
FIRE
EXTINGUISHER
AND
ASCERTAINING
THAT
FIRE
HAS
BEEN
EXTINGUISHED,
VENTILATE
THE
CABIN.
6.
Vents/Cabin
Air/Heat
--
OPEN
when
it
is
ascertained
that
fire
is
completely
extinguished.
!
If
fire
has
been
extinguished
and
electrical
power
is
necessary
for
continuance
of
flight
to
nearest
suitable
airport
or
landing
area:
7.
8.
9.
10.
11.
Master
Switch
--
ON.
Circuit
Breakers
--
CHECK
for
faulty
circuit,
do
not
reset.
Radio
Switches
--
OFF.
Avionics
Master
Switch
--
ON.
Radio/Electrical
Switches
--
ON
one
at
a
time,
with
delay
after
each
until
short
circuit
is
localized.
CABIN
FIRE
1.
Master
Switch
-
OFF.
2.
Vents/Cabin
Air/Heat
-
CLOSED
(to
avoid
drafts).
3.
Fire
Extinguisher
-
ACTIVATE
(if
available).
A
WARNING
4.
5.
AFTER
DISCHARGING
FIRE
EXTINGUISHER
AND
ASCERTAINING
THAT
FIRE
HAS
BEEN
EXTINGUISHED,
VENTILATE
THE
CABIN.
Vents/Cabin
Air/Heat
--
Open
when
it
is
ascertained
that
fire
is
completely
extinguished.
Land
the
airplane
as
soon
as
possible
to
inspect
for
damage.
I
3-8
Revision
7
All manuals and user guides at all-guides.com

Table of Contents

Other manuals for Textron Cessna 172R

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Textron Cessna 172R and is the answer not in the manual?

Textron Cessna 172R Specifications

General IconGeneral
BrandTextron
ModelCessna 172R
CategoryAircrafts
LanguageEnglish

Related product manuals