EasyManuals Logo

Thecus 1U4600 User Manual

Thecus 1U4600
185 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #83 background imageLoading...
Page #83 background image
83
RAID 5 Data striping and stripe error correction information provided.
RAID 5 requires a minimum of 3 disks. RAID 5 can sustain one
failed disk.
RAID 6 Two independent parity computations must be used in order to
provide protection against double disk failure. Two different
algorithms are employed to achieve this purpose. RAID 6 requires
a minimum of 4 disks. RAID 6 can sustain two failed disks.
RAID 10 RAID 10 has high reliability and high performance. RAID 10 is
implemented as a striped array whose segments are RAID 1
arrays. It has the fault tolerance of RAID 1 and the performance of
RAID 0. RAID 10 requires 4 disks. RAID 10 can sustain two failed
disks.
RAID 50(N8900) RAID 50 combines the straight block-level striping of RAID 0 with
the distributed parity of RAID 5. This is a RAID 0 array striped
across RAID 5 elements. It requires at least 6 drives.
RAID 60(N8900) RAID 60 combines the straight block-level striping of RAID 0 with
the distributed double parity of RAID 6. That is, a RAID 0 array
striped across RAID 6 elements. It requires at least 8 disks.
Edit RAID
On the RAID Information screen, press the Edit button to go to the RAID
Information screen.
Using Edit RAID, you can select RAID ID and the Spare Disk. .
WARNING
If the administrator improperly removes a hard disk that should not be
removed when RAID status is degraded, all data will be lost.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Thecus 1U4600 and is the answer not in the manual?

Thecus 1U4600 Specifications

General IconGeneral
BrandThecus
Model1U4600
CategoryNetwork Storage Server
LanguageEnglish

Related product manuals