6 Technical data
6.1 Atec
6.1.1 Technical data
Atec 6 kW 9 kW 11 kW 13 kW 16 kW 18 kW
Type Air/Water
Refrigerant Type
R40
7C
Amount Kg 4,0 4,3 5,0 5,1 5,
6
5,6
Test pressurisation MPa 3,4
Design pressure Mpa 3,1
Compressor Type Scroll
Oil POE
Electrical data 3-
N 50Hz heat
pump
Mains power supply V 400
Rated output, compres-
sor
kW 2,2 2,9 3,3 4,2 5,0 6,1
Rated output, fan kW 0,18 0,28 0,72
Start current
10
A 12 10 18 17 18
Fuse A 10 16
Electrical data 3-
N, 50Hz control
unit
Mains power supply V 230/400
Rated output, circ.
pump
8
kW 0,07 0,14
Auxiliary heater, 5 step
8
kW 3/6/9/12/15
Fuse A
10
12
/16
13
/16
14
/20
15
/25
16
Electrical data 1-
N 50Hz heat
pump
Mains power supply V 230
Rated output, compres-
sor
kW 2,4 2,8 3,6 4,3 5,5 -
Rated output, fan kW 0,18 0,28 -
Start current
10
A 11 21 26 28 -
Fuse A 20 32 32 -
Electrical data 1-
N, 50Hz control
unit
Mains power supply V 230
Rated output, circ.
pump
8
kW 0,07 0,14
Auxiliary heater, 3 step
8
kW 3/6/9
Fuse A
16
17
/30
18
/40
19
Planning guide Atec
VIIFB102 Thermia Värmepumpar
18
Atec
Energy eciency class
Energy eciency class built in temperature control package
Energy eciency class (low temperature applications)
Energy eciency class built in temperature control package
(low temperature applications)
Declared load prole
Energy label water heater
A+
A+
A+
A+
B
A++
A++
A+
A+
XLXL
A
A+
A+
A++
A++
XL
A
A++
A++
A++
A++
XL
A
A+
A+
A++
A++
XXL
B
A+
A+
A+
A+
XXL
B
6 kW 9 kW 11 kW 13 kW 16 kW 18 kW