Caution The unit with water heater must be placed indoors, in an area with a floor drain.
Caution The unit with water heater must be placed indoors, on a stable surface. The floor must be able to support the
gross weight of the unit with filled water tank (see Technical data).
N
Avoid placing the heat pump near windows or walls to noise sensitive areas.
N
Ensure that there is sufficient distance to neighbouring properties so that they are not exposed to noise. Ap-
plicable local regulations must be followed.
N
The heat pump should not be enclosed.
N
Keep the heat pump and its immediate area free of snow, ice, leaves etc.
N
Remember that the heat pump must have a certain amount of space in order to function and for servicing.
Otherwise there is a risk that the air will recirculate from exhaust to intake. Avoid this by following the dimen-
sions given below.
>
5
0
0
m
m
>
5
0
0
m
m
>1500
m
m
>
4
0
0
m
m
>
5
0
0
m
m
1.3.2 Lifting instructions
To lift the heat pump into position, unscrew the side plates by slackening off the screws (1).
Then use the side members behind the side panels to lift and position the heat pump.
Planning guide Atec
VIIFB102 Thermia Värmepumpar
6