8 SERVICE menu
8.1 Menu overview
To be able to chose a specific function, the sensor for that function
must be connected.
▪
HOT WATER
▪
HEATING
▪
COOLING
▪
POOL
▪
AUX. HEATER
▪
MANUAL TEST
▪
INSTALLATION
▪
SYSTEM
▪
HEAT SOURCE/AIR/DIRECT EVAP.
▪
POOL
▪
DISTR. CIRCUIT 1
▪
DISTR. CIRCUIT 2
▪
BUFFER TANK
▪
OPTIMUM
▪
CURRENT LIMITER
▪
SERVICE TIME
▪
FACTORY SET
▪
RESET OPER. TIME
▪
SENSOR CALIBRATION
▪
VERSION
▪
LOG TIME
▪
DEFROST
▪
OPTIMUM
▪
BUFFER TANK
▪
OUTD. UNIT INFO
8.2
HOT WATER
Parameter Meaning
START Start temperature for hot water production, in COMFORT-, ECO- and AWAY mode. Shows the actual weighted
hot water temperature and the value within brackets indicates the start temperature. ( = no hot water pro-
duction)
(COMFORT and ECO) Factory setting: 40°C, range: , 30°C – 55°C
(AWAY) Fixed start temperature: 25°C
STOP The weighted hot water temperature for stopping hot water production during operation with only compres-
sor, in COMFORT-, ECO- and AWAY mode.
(COMFORT and ECO) Factory setting: 50 With ECO-mode it is fixed at 49 °C and in COMFORT-MODE possible to
change. Range: START + 1K – 65°C
(AWAY) Fixed stop temperature: 30°C
Commissioning iTec XT
AWIXT01CG0102 Thermia AB