Caution All warranties from Thermia are void if, when filling with refrigerant
other than not valid specified refrigerant, if there has not been written
notification that the new refrigerant is an approved replacement re-
frigerant together with other remedies.
2.2.5 Scrapping
Caution When the heat pump is to be scrapped the refrigerant must be extrac-
ted for disposal. Local rules and regulations related to the disposal of
refrigerant must be followed.
2.3 Commissioning
Caution The installation may only be commissioned if the heating system has
been filled and bled. Otherwise the circulation pump can be damaged.
Caution If the installation is only to be driven by the immersion heater during
the installation, ensure that the heating system is filled and compres-
sor cannot be started.
Commissioning iTec
Thermia Värmepumpar VIJSR102
9