7.5 In the event of leakage
In the event of leakage in the hot water pipes between the heat pump and water taps, close the shut-off valve
on the cold water inlet immediately. Then contact your installer.
In the event of leakage in the brine circuit, turn off the heat pump and call your installer immediately.
7.6 Cleaning the filters for the heating and brine circuits
N
Contact your installer if you are not sure how
to perform the filter cleaning.
N
The heat pump must be switched off at the
main switch before cleaning can be started.
N
The cleaning of filters may cause air ingress to
the brine or heating system that may cause
operational disturbances.
N
Check and clean the filters at least twice the
first year after installation. The interval can be
extended if there is evidence that cleaning
twice a year is not necessary.
N
Have a cloth at hand when opening the filter
cover as a small amount of water usually es-
capes.
A
D
C
B
A Shut-off tap
B Cover
C Filter
D O-ring
User Guide Mega