21
5.4. Connecting the VX-3000DS to VX-3000 System
5.4.1. DC power output terminal connections
Required power is supplied to the system from a single power supply unit.
Note
A redundant power system of the VX-3000DS cannot be applied to the VX-3004F, VX-3008F, and VX-3016F.
Notes
Total number of the connected devices Total output power
VX-015DA, VX-030DA, VX-050DA Max. 8 units 2000 W or less
FUSE 35A
(POWER OUT)
BATTERY POWER IN
24V MAX 150A
POWER OUT(
-
)
1234567
POWER OUT(+) 19-33V MAX 25A
WARNING
Take special care to prevent the battery
from being shorted by misconnection
of the battery cable.
If the shore occurs, the unit may fail.
OUT
DS LINK
16-24V MAX 0.3A
POWER OUT
TEMPERATURE
SENSOR
8
IN
POWER OUT(
-
)
POWER OUT(+) 19 – 30V MAX 25A
3 1
d c ab
h g ef
b f ea
d h gc
VX-3000DS
4P removable terminal plug
(supplied with the VX-3004F, VX-3008F, and VX-3016F)
(DC power input terminal) (DC power input terminal)
VX-3004F, VX-3008F, or VX-3016F
VX-3004F, VX-3008F, or VX-3016F
This figure represents the VX-3004F.
This figure represents the VX-3016F.
Amplifier DC power input terminal
(VX-015DA, VX-030DA, or VX-050DA
Digital power amplifer module)
Amplifier DC power input terminal (VX-015DA, VX-030DA, or VX-050DA)
+
+
-
-
230 V AC
220 V AC
50/60 Hz
Cable: AWG 18 – AWG 14