43
MultiLoad II DC Permissive/Status Wiring
5.4.7
I/O DIGITAL/
ANALOG
I/O 2 METER
METER 0 METER 1
PORT 5
PORT 4.-
PORT 5.-
PORT 4.+
PORT 5.+
PORT 4
PORT 7
PORT 6
PORT 9
IO_DA ONLY!
PORT 6.+
PORT 7.+
PORT 9.+
PORT 6.-
PORT 7.-
PORT 9.-
+
1
-
2
+
3
-
4
+
5
-
6
+
7
-
8
+
9
-
10
IO_DA TB2B
PORT 4
PORT 5
PORT 6
PORT 7
PORT 9
+
1
-
2
+
3
-
4
+
5
-
6
PORT 5
PORT 7
IO_2M TB7
PORT 4
+
1
-
2
+
3
-
4
+
5
-
6
PORT 5
PORT 7
IO_2M TB8
PORT 4
IO_DA ONLY!
+
-
&
+
-
+
-
+
-
+
-
+
-
5 30 Vdc
M
L
N
L
N
Note: This shows a typical configuration. DC Permissive/Status inputs can be assigned to any unused DC input.