14 Instructions for Use TORMAX 2201 T-1165 e
7.2 Check-list for Functional Checks
Item To Be Checked Procedure Resultat
Sensors
• Walk through the door direct-
ly from the front and from dif-
ferent directions at normal
speed, starting both from the
inside and outside
The door opens at the right time
and with sufficient speed so that
passage through the door Is not
hindered.
Safety Sensors
T1321_7
• Walk through the door direct-
ly from the front and from dif-
ferent directions at a slow
speed like an infirm person,
starting both from the inside
and outside.
The door opens and remains
open until you are completely
through the door.
Moving Leaves, Side Parts, Fixed Leaves
• Check the glass door fillings,
door edges and rubber pro-
files for damage.
The door fillings have no sharp
edges and splintered glass.
The side parts and the door
seals are in place and undam-
aged.
Guide System and Door Guides
• Check the noises made
while the door moves.
No unusual and noticeable
movement noises can be heard
in the drive, guide system or
floor guides.
Cladding
iMotion 2301 / 2401 iMotion 2202
• Check whether the cladding
is correctly slotted into place
and secured.
The cladding is firmly slotted
into place.
Operating Controls
3
• Check the function and
marking of operating con-
trols.
The operating controls are func-
tioning correctly; the markings
are visible and legible.
System Vicinity
T1321_12
• Check access to the door
and the movement area of
the door leaves.
Access to the door is free from
objects and items likely to cause
the user to trip. There are no
objects such as shelves, plant
containers and umbrella stands
within a radius of 50 cm of the
movement area.