BLOWER MOTOR ASSEMBLY
(MODELS 98800 / 98801 / 98900)
TO MOUNT MOTOR UNIT TO VACUUM TANK COVER:
Place unit intake neck into locking collar and turn 90
degrees clockwise.
MAINTENANCE OF MOTOR UNIT
:
Damage to an armature invariably is caused by
permitting carbon brushes to become worn to less than
1/4 inch in length. To prevent this occurrence, inspect
brushes after 200 hours operation and frequently
thereafter, replacing when necessary. Failure to do so
will nullify our warranty.
To inspect brushes, unplug cord, remove top cover by
removing screws and release brush spring, pull brushes
out and check.
NO OTHER MAINTENANCE OF MOTOR SHOULD BE
ATTEMPTED DURING FIRST YEAR AFTER
PURCHASE (SEE WARRANTY).