•Performarecovery-regenerationwhenever
thereisalossofenginepowerandaparked
regenerationcannoteffectivelycleantheDPFof
soot.
•Arecoveryregenerationrequiresupto4hours
tocomplete.
•Youneedadistributortechniciantoperformthe
recoveryregenerationprocess;contactyour
AuthorizedT oroDistributor.
AdjustingtheLift-Arm
Counterbalance
Youcanadjustthecounterbalanceontherear
cutting-unitliftarmstocompensatefordifferentturf
conditionsandtomaintainauniformheightofcutin
theroughconditionsorinareasofthatchbuild-up.
Youcanadjusteachcounterbalancespringto1of
4settings.Eachincrementincreasesordecreases
counterbalanceonthecuttingunitby2.3kg(5lb).
Youcanpositionthespringsonthebacksideofthe
rstspringactuatortoremoveallcounterbalance
(fourthposition).
1.Positionthemachineonalevelsurface,lower
thecuttingunits,stoptheengine,engagethe
parkingbrakes,andremovethekeyfromignition
switch.
2.Insertatubeorsimilarobjectontothelong
springendandpivotitaroundthespringactuator
tothedesiredposition(Figure54).
CAUTION
Thespringsareundertension.
Usecautionwhenadjustingthem.
g019276
Figure54
1.Spring2.Springactuator
3.Repeattheprocedureontheotherspring.
AdjustingtheLift-Arm
TurnaroundPosition
1.Positionthemachineonalevelsurface,lower
thecuttingunits,stoptheengine,engagethe
parkingbrakes,andremovethekeyfromignition
switch.
2.Thelift-armswitchislocatedunderneaththe
hydraulictankbehindthefront,rightliftarm
(Figure55).
3.Loosentheswitch-mountingscrewsand
movetheswitchdowntoincreasethelift-arm
turnaroundheightormovetheswitchupto
decreasetheliftarmturnaroundheight(Figure
55).
g012154
Figure55
1.Switch2.Lift-armsensingdevice
4.Tightenthemountingscrews.
PushingorTowingthe
Machine
Inanemergency,youcanmovethemachine
byactuatingthebypassvalveinthevariable
displacementhydraulicpumpandpushingortowing
themachine.
Important:Donotpushortowthemachinefaster
than3to4.8km/h(2to3mph)becauseinternal
transmissiondamagemayoccur.Thebypass
valvemustbeopenwheneveryoupushortow
themachine.
1.Rotatethebypass-valvebolt1-1/2turnstoopen
andallowoiltobypassinternally(Figure56).
Note:Thebypassvalveislocatedontheleft
sideofthehydrostat.Bybypassingtheuid,you
canmovethemachineslowlywithoutdamaging
thetransmission.
40