EasyManua.ls Logo

Toro 03606A - Sound Power Level; Sound Pressure Level; Vibration Level; Engine Emission Certification

Toro 03606A
64 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
loweringthecuttingunitsandattachmentstothe
ground.
•Checkallfuellinesfortightnessandwearona
regularbasis.Tightenorrepairthemasneeded.
•Iftheenginemustberunningtoperforma
maintenanceadjustment,keephands,feet,
clothing,andanypartsofthebodyawayfromthe
cuttingunits,attachments,andanymovingparts.
Keepeveryoneaway.
•Toensuresafetyandaccuracy,haveanAuthorized
ToroDistributorcheckthemaximumenginespeed
withatachometer.
•Ifmajorrepairsareeverneededorifassistanceis
desired,contactanAuthorizedT oroDistributor.
•UseonlyToro-approvedattachmentsand
replacementparts.Thewarrantymaybevoidedif
usedwithunapprovedattachments.
SoundPowerLevel
Model03606
Thisunithasaguaranteedsoundpowerlevelof103
dBA,whichincludesanUncertaintyValue(K)of1
dBA.
Soundpowerlevelwasdeterminedaccordingtothe
proceduresoutlinedinISO11094.
Model03607
Thisunithasaguaranteedsoundpowerlevelof105
dBA,whichincludesanUncertaintyValue(K)of1
dBA.
Soundpowerlevelwasdeterminedaccordingtothe
proceduresoutlinedinISO11094.
SoundPressureLevel
Model03606
Thisunithasasoundpressurelevelattheoperator’s
earof86dBA,whichincludesanUncertaintyValue
(K)of1dBA.
Soundpressurelevelwasdeterminedaccordingto
theproceduresoutlinedinENISO5395:2013.
Model03607
Thisunithasasoundpressurelevelattheoperator’s
earof84dBA,whichincludesanUncertaintyValue
(K)of1dBA.
Soundpressurelevelwasdeterminedaccordingto
theproceduresoutlinedinENISO5395:2013.
VibrationLevel
Model03606
Hand-Arm
Measuredvibrationlevelforrighthand=0.66m/s
2
Measuredvibrationlevelforlefthand=0.98m/s
2
UncertaintyValue(K)=0.5m/s
2
Measuredvaluesweredeterminedaccordingtothe
proceduresoutlinedinENISO5395:2013.
WholeBody
Measuredvibrationlevel=0.31m/s
2
UncertaintyValue(K)=0.15m/s
2
Measuredvaluesweredeterminedaccordingtothe
proceduresoutlinedinENISO5395:2013.
Model03607
Hand-Arm
Measuredvibrationlevelforrighthand=0.84m/s
2
Measuredvibrationlevelforlefthand=0.77m/s
2
UncertaintyValue(K)=0.5m/s
2
Measuredvaluesweredeterminedaccordingtothe
proceduresoutlinedinENISO5395:2013.
WholeBody
Measuredvibrationlevel=0.27m/s
2
UncertaintyValue(K)=0.15m/s
2
Measuredvaluesweredeterminedaccordingtothe
proceduresoutlinedinENISO5395:2013.
EngineEmission
Certication
TheengineinthismachineisEPATier4Finaland
stage3bcompliant.
7