g004150
Figure91
1.Hydrauliclter
3.Removethelter.
4.Lubricatethegasketonthenewlterwith
hydraulicoil.
5.Ensurethatthelter-mountingareaisclean.
6.Installthelterbyhanduntilthegasketcontacts
themountingsurface,thenrotateitanadditional
1/2turn.
7.Repeattheprocedureontheotherlter.
8.Starttheengineandletitrunforabout2minutes
topurgeairfromthesystem.
9.Stoptheengineandcheckforleaks.
CheckingtheHydraulic
LinesandHoses
Daily,checkhydrauliclinesandhosesforleaks,kinked
lines,loosemountingsupports,wear,loosettings,
weatherdeterioration,andchemicaldeterioration.
Makeallnecessaryrepairsbeforeoperating.
WARNING
Hydraulicuidescapingunderpressurecan
penetrateskinandcauseinjury.
•Makesurethatallhydraulicuidhoses
andlinesareingoodconditionandthatall
hydraulicconnectionsandttingsaretight
beforeapplyingpressuretothehydraulic
system.
•Keepyourbodyandhandsawayfrom
pinholeleaksornozzlesthatejecthigh
pressurehydraulicuid.
•Usecardboardorpapertondhydraulic
leaks.
•Safelyrelieveallpressureinthehydraulic
systembeforeperforminganyworkonthe
hydraulicsystem.
•Getimmediatemedicalhelpifuidis
injectedintotheskin.
Hydraulic-SystemTest
Ports
Usethehydraulic-systemtestportstotestthe
pressureinthehydrauliccircuits.Contactyourlocal
Torodistributorforassistance.
Usethetestportsonthefronthydraulictubestoassist
introubleshootingthetractioncircuit(Figure92).
59