Page 5 -- 12
Electrical System
Fuse Block
Fusescanberemovedtocheckcontinuity.Thetestme-
ter should read less than 1 ohm.
Fuses supply power to the following (Fig. 8):
1. Fuse F1 (top) (10 ampere)suppliespowertotherun
and mow relays.
2. FuseF2(10ampere)suppliespowertother aiseand
lower relays.
3. FuseF3(15ampere)suppliespowertoterminalBof
the ignition switch.
4. FuseF4isavailableforoptionalaccessories.Amax-
imum 15 ampere fuse should be used in this position.
Figure 8
F1
F2
F3
F4
F1
F2
F3
Hour Meter
1. Connectthepositive(+)terminalofa12VDCsource
to the positive terminal of the hour meter.
2. Connect the negative (--) terminal of the voltage
source to the other terminal of the hour meter.
3. The hour meter should move a 1/10 of an hour in six
(6) minutes.
4. Disconnect the voltage source from the hour meter.
Figure 9