Greensmaster 3250--D
Page 5 -- 23
Electrical System
Glow Relay
When energized by the glow plug controller, the glow
relay allows electrical current to the engine glow plugs.
The glow relay is attached to a frame bracket near the
fuseblock(Fig.27)andisconnectedtothewireharness
with a four (4) wire connector (Fig. 28).
Relay Testing
1. Disconnect wire harness connector from glow relay.
2. Toalloweasieraccesstorelayterminals,eitherloos-
enfastenersthatsecurerelaytobracketorremoverelay
from bracket.
3. Verify coil resistance between terminals 86 and 85
with a multimeter (ohms setting). Resistance should be
from 41 to 51 ohms.
4. Connectmultimeter(ohmssetting)leadstorelayter-
minals 30 and 87. Ground terminal 86 and apply +12
VDC to terminal 85. The relay should make and break
continuitybetweenterminals30and87as12VDCisap-
plied and removed from terminal 85.
5. When testing is complete, disconnect voltage and
multimeter leads from relay terminals.
6. Replace glow relay if testing determines that it is
faulty.
7. Connect wire harness connector to glow relay.
8. Secure glow relay to bracket.
Figure 27
1. Fuse block
2. Cap screw
3. Glow relay
4. Lock nut
1
2
3
4
Figure 28
86 87
85 30
85 86
87
30
Electrical
System