Greensmaster 3250--D
Page 5 -- 15
Electrical System
Lower Reels Time Delay
Thelowerreelstimedelayisasolidstatetimer.Uponthe
application of power, the load is energized and the time
delay is started. After six (6) seconds the load isde--en-
ergized. The time delay is attached to a bracket under
the control console (Fig. 13).
Testing
1. Connect voltmeter across test load and test load to
timer. Connect 12VDC source to timer and load. Make
sure to observe polarity. After six (6) seconds, there
should be no voltage across the load.
2. When testing is completed, disconnect timer from
12VDC source and test load.
Figure 13