9. Remove the two bolts securing the pivot arm
tensioner and remove tensioner and spring (Fig.
101).
Fig. 101 tensioner
11. Disconnect hydro hoses from the overow tank and
plug the openings (Fig. 103). Ensure shop towels or
rags are available to wipe up any uid spills. Dispose
of used towels properly (Fig. 104).
Fig. 103 hose
Fig. 104 towel
10. Remove the stationary idler on the RH side of the
unit (Fig. 102).
Fig. 102 idler