EasyManua.ls Logo

Toro 25500 - Servicing the Transmission

Toro 25500
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
CleaningtheAxleBreathers
ServiceInterval:Every1,000hours
1.Cleantheareaaroundthebreatherswithacleaning
solvent(Figure91andFigure92).
Figure91
1.Breathertting
2.Frontaxle
Figure92
1.Breathertting
2.Rearaxle
2.Removethebreathersfromthefrontaxleandrear
axles(Figure91andFigure92).
3.Cleanthebreatherswithacleaningsolvent.
4.Usecompressedairtodrythebreathers.
Important:Wearfaceprotectionwhenusing
compressedair.
5.Installthebreathersintothefrontandrearaxles(Figure
91andFigure92).
ServicingtheTransmission
Transmission-oilspecication:Mobiluid424
CheckingtheOilLevelinthe
Transmission
ServiceInterval:Every100hours
Important:Ifyouoperatethemachinewhilethelevelof
thetransmissionoilisbelowtherecommendedlevel,you
maydamagethetransmissionandtheparkingbrake.
1.Parkthemachineonalevelsurface.
2.Starttheengineandrunitfor10minutes.
3.Stoptheengineandremovetheignitionkey.
4.After5minutes,checkthetransmissionoillevelinthe
sightgauge(Figure93).
Note:Theoillevelshouldcover1/2to3/4ofthe
sight-gaugewindow .
Figure93
1.Sightgauge
5.Iftheoillevelislow,addthespeciedoilintothe
transmission;refertoFillingtheTransmissionwithOil
(page61).
6.Repeatsteps2through5untiltheoillevelcovers1/2
to3/4ofthesight-gaugewindow(Figure93).
Note:Asyouaddoiltothetransmission,perform
steps2through4todeterminethecorrectedoillevel.
60

Table of Contents

Related product manuals