3.Installthebatteryinthemachineandconnect
thebatterycables,refertoInstallingtheBattery
(page40).
Note:Donotrunthemachinewiththebattery
disconnected;electricaldamagemayoccur.
g000960
Figure39
1.Positivebatterypost
3.Red(+)chargerlead
2.Negativebatterypost
4.Black(-)chargerlead
ServicingtheFuses
Theelectricalsystemisprotectedbyfuses.Itrequires
nomaintenance;however,ifafuseblowscheckthe
component/circuitforamalfunctionorshort.
1.Thefusesarelocatedonrightsidebehindthe
seat.
2.Toreplacethefuses,pulloutonthefuseto
removeit.
3.Installanewfuse.
AdjustingtheSafety
Switches
Adjustallsafetyswitchessothattheplungerextends
4.8mmto6.4mm(3/16inchto1/4inch)fromthe
switchbodywhentheplungeriscompressed(Figure
40).
g006849
Figure40
1.4.8to6.4mm(3/16to1/4inch)
Jump-StartingtheMachine
1.Checkandcleancorrosionfromthebattery
terminalsbeforejump-starting.
Note:Ensurethattheconnectionsaretight.
CAUTION
Corrosionorlooseconnectionscan
causeunwantedelectricalvoltagespikes
atanytimeduringthejump-starting
procedure.
Donotattempttojump-startthemachine
withlooseorcorrodedbatteryterminals,
ordamagetotheengineorEFImay
occur.
DANGER
Jump-startingaweakbatterythatis
cracked,frozen,hasalowelectrolyte
level,orhasanopen/shortedbattery
cellcancauseanexplosion,resultingin
seriouspersonalinjury.
Donotjump-startaweakbatteryifthese
conditionsexist.
2.Makesurethattheboosterbatteryisagood
andfullychargedlead-acidbatteryat12.6Vor
greater.
Note:Useproperlysizedjumpercableswith
shortlengthstoreducevoltagedropbetween
41