AssistDPFRegeneration
Theenginecomputeradjustsenginesettingsto
raisetheexhausttemperature.
Whileoperatingthemachine,runtheengineat
fullenginespeedandhighloadwhenpossibleto
promoteDPFregeneration.
ResetRegeneration
CAUTION
Theexhausttemperatureishot(approximately
600°C(1,112°F)duringDPFregeneration.Hot
exhaustgascanharmyouorotherpeople.
Neveroperatetheengineinanenclosed
area.
Makesurethattherearenoammable
materialsaroundtheexhaustsystem.
Nevertouchahotexhaustsystem
component.
Neverstandnearoraroundtheexhaust
pipeofthemachine.
g224417
Figure34
Thehighexhaust-temperatureicondisplays
intheInfoCenter(Figure34).
Theenginecomputeradjustsenginesettingsto
raisetheexhausttemperature.
Important:Thehighexhaust-temperature
iconindicatesthattheexhausttemperature
dischargedfromofyourmachinemaybe
hotterthanduringregularoperation.
Whileoperatingthemachine,runtheengineat
fullenginespeedandhighloadwhenpossibleto
promoteDPFregeneration.
TheicondisplaysintheInfoCenterwhilethereset
regenerationisprocessing.
Wheneverpossible,donotshutofftheengineor
reduceenginespeedwhiletheresetregeneration
isprocessing.
Important:Wheneverpossible,allowthe
machinetocompletetheresetregeneration
processbeforeshuttingofftheengine.
PeriodicResetRegeneration
IftheenginehasnotcompletedasuccessfulReset,
Parked,orRecoveryregenerationintheprevious100
hoursofengineoperation,theenginecomputerwill
attempttoperformaresetregeneration.
SettingtheInhibitRegen
ResetRegenerationOnly
Note:IfyousettheInfoCentertoinhibitregeneration,
theInfoCenterdisplaysADVISORY#185(Figure35)
every15minuteswhiletheenginerequestsareset
regeneration.
g224692
Figure35
Aresetregenerationproducestheelevatedengine
exhaust.Ifyouareoperatingthemachinearound
trees,brush,tallgrass,orothertemperature-sensitive
plantsormaterials,youcanusetheInhibitRegen
settingtopreventtheenginecomputerfrom
performingaresetregeneration.
Important:Whenyoushutofftheengineand
startitagain,theinhibitregensettingdefaultsto
OFF.
1.AccesstheDPFRegenerationmenu,pressthe
centerbuttontoscrolldowntotheINHIBITREGEN
option,andpresstherightbuttontoselectthe
InhibitRegenentry(Figure36).