EasyManua.ls Logo

Toro Groundsmaster 4300-D - DPF Regeneration Messages and Actions; Check Message and Corrective Action Table

Toro Groundsmaster 4300-D
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5.TheInfoCenterdisplaystheINITIATINGDPF
REGENmessage(Figure54).
g224411
g227681
Figure54
6.TheInfoCenterdisplaysthetimetocomplete
message(Figure55).
g224406
g224406
Figure55
7.Theenginecomputercheckstheenginestate
andfaultinformation.TheInfoCentermay
displaythefollowingmessagesfoundinthe
tablethatfollows:
Note:Ifyouattempttodoaforcedparked
regenerationbefore50hoursofthelast
sucessfulregenerationthismessagewillappear.
Ifthemachineisrequestingaregenerationand
thismessageappearscontactyourauthorized
Torodistributorforservice.
CheckMessageandCorrectiveActionTable
CorrectiveAction:Exittheregenerationmenuandrunthe
machineuntilthetimesincelastregenerationisgreaterthan
50hours;refertoTimeSinceLastRegeneration(page38).
CheckMessageandCorrectiveActionTable
(cont'd.)
CorrectiveAction:Troubleshoottheenginefaultandretry
DPFregeneration.
CorrectiveAction:Startandruntheengine.
CorrectiveAction:Runtheenginetowarmthecoolant
temperatureto60°C(140°F).
CorrectiveAction:Changetheenginespeedtolowidle.
CorrectiveAction:Troubleshoottheenginecomputer
conditionandretryDPFregeneration.
8.TheInfoCenterdisplaysthehomescreenand
theregenerationacknowledgeicon(Figure56)
appearsinthelowerrightcornerofthescreen
astheregenerationprocesses.
g224403
Figure56