17
1  Select SET AUXILIARIES on the Control Dial. 
2  Press the     button repeatedly until STATION 
DELAY appears in the bottom left hand corner 
of the screen. The Station No will be flashing.
3  Use the         and         buttons to select the 
required Station No.
4  Press         and OFF will flash. 
5  Press         repeatedly until the required delay 
time is reached (1 to 99 seconds). Setting the 
time to 0 or 100 will reset the delay to OFF.
6  Press         and the Station No will flash. 
7  Repeat steps 4 to 6 until the delay has been 
set for all required Stations.
MASTER VALVE ON/OFF SELECTION
3  Use the         and         buttons to select the 
required Station No.
4  Press         and OFF will flash. 
5  Press         repeatedly until the required delay 
time is reached (1 to 99 seconds). Setting the 
time to 0 or 100 will reset the delay to OFF.
6  Press         and the Station No will flash. 
7  Repeat steps 4 to 6 until the delay has been 
set for all required Stations.
STATION DELAY
Station delay is used to reduce complications caused if one valve is slow to close and the next valve 
opens before that valve has closed. Station delay adds a short delay in valve operation, meaning the next 
valve in the watering sequence is opened slightly after the previous one is closed.
Dierent delays can be set for each Station and the value can be between 0 (OFF) and 99 seconds.