Specifications
Line Voltage: 115-120 or 230-240 VAC 50/60 Hz (switchable), 130 VA
Current Draw (no load): 0.20A @ 115-120 VAC, 60 Hz or 0.10A @ 230-240 VAC, 50 Hz
Current Draw (maximum load): 1.20A @ 115-120 VAC, 60 Hz or 0.60A @ 230-240 VAC, 50 Hz
Current Load (based on available 24 VAC)
Maximum Current Available for Load: 3.0A (85 VA)
Maximum Load Per Station:0.75A (18 VA)
Maximum Load Per Pump/Master Valve: 1A (24 VA)
Operating Temperature: -10°C to +60°C (14°F to 140°F)
Storage Temperature: -30°C to +65°C (-22°F to 149°F)
Battery Backup:
(Specs TBD)
Hardware Features
Plastic or Painted Stainless-Steel Cabinetry
Front, Back and Top Locking Covers
Removable Station Output and Common/Pump Modules
Modular Station Output: 16 to 64 stations in 8-station increments
Optional Surge Protection Modules for Field and Communication Circuits
Fuses and Circuit Breakers
Power Supply:
1.5A On/Off Switch/Circuit Breaker – Main Power Input
3.2A Fuse (Slow-Blow) – Field Output
4.0A Circuit Breaker – Control Functions (Timing Mechanism)
Pump/Common & Communication Surge Protection Module (optional): 1A Fuse
WARNING
IF FUSE REPLACEMENT IS REQUIRED, REPLACE WITH A FUSE OF THE SAME TYPE AND AMPERAGE RATING.
FAILURE TO COMPLY CAN RESULT IN SERIOUS INJURY AND/OR EQUIPMENT DAMAGE DUE TO FIRE HAZARD.