7
RoutingtheWiringHarness
Partsneededforthisprocedure:
1
Consolewiringharness
1Blowerwiringharness
10
Cabletie
1
Switch
1Fuse
1Fuseblock
Procedure
1.Routetheconsole-wiringharnessalongthelift
frameandthroughthemachine.
2.Plugtheconnectorintothefuseblock(Figure9).
g029724
Figure9
1.Fuse
5.Ground
2.Fuseblock
6.Tofuseblock
3.Switch
7.Toattachment
4.Switchconnector
3.Plugthefuseintothefuseblock(Figure9).
Note:Iftherearenoopenslotsintheexisting
fuseblock,usetheadditionalfuseblock
providedinthekit.
4.Connecttheground-ringterminaltotheground
block(Figure9).
5.Removetheknockoutplugfromthecontrol
panel,placetheswitchinthehole,andconnect
theconsole-wiringharnesstotheswitch(Figure
10).
g029725
Figure10
1.PTOswitch—bloweron/off3.Switch
2.Knockoutplug
6.Usecabletiestosecuretheconsole-wiring
harnesstothemachineandtheliftarm(Figure
11).
g029763
Figure11
1.Console-wiringharness
3.Blower-wiringharness
2.Harnessconnectors
7