EasyManua.ls Logo

Toro Reelmaster 5500-D - Installation; Removal

Toro Reelmaster 5500-D
290 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Cutting Units
Reelmaster 5500-D Page 8 - 19 Cutting Units
Removal
1. Loosen bedknife adjusting knob to loosen bedknife to
reel contact.
2. Loosen locknut on bedknife adjuster assembly and
disengaging adjuster from bedbar (Fig. 26).
3. Remove bedbar leveling screw from L.H. side of cut-
ting unit.
4. Remove fasteners securing L.H. and R.H. bedbar
pivot hubs to frame.
5. Remove bedbar assembly.
6. Remove capscrew, washer and quad ring from R.H.
end of bedbar.
7. Remove R.H. and L.H. pivot hubs from bedbar.
8. Sharpen or replace bedknife as necessary (see Bed-
knife Replacement and Grinding).
Installation
1. Inspect bedbar end bushings and flange bushings for
wear and replace if necessary.
2. Install R.H. and L.H. pivot hubs onto bedbar.
3. Install quad ring, washer and capscrew to R.H. end of
bedbar.
4. Install bedbar onto cutting unit and secure pivot hubs
to frame with fasteners removed in step 4 above.
5. Install bedbar leveling capscrew and nuts to L.H. side
of cutting unit.
6. Install bedknife adjusting knob assembly. Tighten
locknut to compress spring to dimension shown
(Fig. 27).
7. Adjust bedknife to reel (see Bedknife to Reel Adjust-
ment).
Figure 26
1. Bedknife adjusting knob
1
2
2. Locknut
1.25 in. (32 mm)
Figure 27

Table of Contents

Other manuals for Toro Reelmaster 5500-D

Related product manuals