EasyManua.ls Logo

Toro TITAN ZX 4800 - Rollover Protection System (ROPS) Usage; Model Specifications; Model 74846 Specifications; Model 74848 Specifications

Toro TITAN ZX 4800
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
UsingtheRollover-ProtectionSystem
(ROPS)
Keeptherollbarintheraisedandlockedpositionand
usetheseatbeltwhenoperatingthemachine.
Becertainthattheseatbeltcanbereleasedquicklyin
theeventofanemergency.
Beawarethereisnorolloverprotectionwhentheroll
barisdown.
ChecktheareatobemowedandneverfoldtheROPSin
areaswherethereareslopes,dropoffsorwater.
Lowertherollbaronlywhenabsolutelynecessary.Donot
weartheseatbeltwiththerollbarfoldeddown.
Checkcarefullyforoverheadclearances(i.e.branches,
doorways,electricalwires)beforedrivingunderany
objectsanddonotcontactthem.
Model74846
SoundPower
Thisunithasaguaranteedsoundpowerlevelof105dBA,
whichincludesanUncertaintyValue(K)of1dBA.
Soundpowerlevelwasdeterminedaccordingtothe
proceduresoutlinedinISO11094.
SoundPressure
Thisunithasasoundpressurelevelattheoperator’searof92
dBA,whichincludesanUncertaintyValue(K)of1dBA.
Soundpowerlevelwasdeterminedaccordingtothe
proceduresoutlinedinENISO5395:2013.
Hand-ArmVibration
Measuredvibrationlevelforlefthand=4.8m/s2
Measuredvibrationlevelforrighthand=4.4m/s2
UncertaintyValue(K)=2.4m/s2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinENISO5395:2013.
WholeBodyVibration
Measuredvibrationlevel=0.39m/s2
UncertaintyValue(K)=0.19m/s2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinENISO5395:2013.
Model74848
SoundPower
Thisunithasaguaranteedsoundpowerlevelof105dBA,
whichincludesanUncertaintyValue(K)of1dBA.
Soundpowerlevelwasdeterminedaccordingtothe
proceduresoutlinedinISO11094.
SoundPressure
Thisunithasasoundpressurelevelattheoperator’searof92
dBA,whichincludesanUncertaintyValue(K)of1dBA.
Soundpowerlevelwasdeterminedaccordingtothe
proceduresoutlinedinENISO5395:2013.
Hand-ArmVibration
Measuredvibrationlevelforlefthand=5.8m/s2
Measuredvibrationlevelforrighthand=3.6m/s2
UncertaintyValue(K)=2.3m/s2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinENISO5395:2013.
WholeBodyVibration
Measuredvibrationlevel=0.45m/s2
UncertaintyValue(K)=0.22m/s2
Measuredvaluesweredeterminedaccordingtotheprocedures
outlinedinENISO5395:2013.
7

Table of Contents

Related product manuals