59
DeutschEnglish
• Maintenanceworkmustberealizedbyqualiedstaff.
Contact Torqeedo Service.
• Priortoanytechnicalcheckorserviceoperation,servicestaff
must necessarily switch off the DEEP BLUE system. Moreover,
withdraw emergency stop lanyard and wait three minutes before
touching electrical components.
DEEP BLUE service intervals
Serviceintervals:Serviceistobe
carried out in the specified intervals
or after specified operating hours
– whichever occurs first.
Service operations
Once,1monthor
20 operating hours
after commissioning
Permanently
Everysix
months or
after 100
operating
hours
Yearly or
after 200
operating
hours
Battery and battery
cables
Check water tight
xingandisolation
Motor cover
screw joint
Check strength
Otherscrewsand
bolts on outboard
Check strength
Lubrication points Lubricate
*
Gear oil Change
Othercable
connections
Check water tight
xingandisolation
Cooling system
Check tightness
and throughput
Battery venting hoses
Check fastening
and skin
Connections in
connectionbox
Check fastening
Highvolt isolation Check
Battery damping Check
Data display
Check fastening and
tightness
Throttle
Check stability and
function
Clutch Check function
Sacrificial anode Check condition
Impeller Change
* when using the outboard in saltwater, proceed to checks in shorter intervals

Other manuals for Torqeedo Deep Blue

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Torqeedo Deep Blue and is the answer not in the manual?

Torqeedo Deep Blue Specifications

General IconGeneral
BrandTorqeedo
ModelDeep Blue
CategoryOutboard Motor
LanguageEnglish

Related product manuals