61
DeutschEnglish
For any errors which have not been listed or which you cannot remedy by the above
mentioned measures, please contact a Torqeedo service partner.
9. DEEP BLUE capacity warranty for high voltage batteries
Torqeedo GmbH, Friedrichshafener Straße 4a D-82205 Gilching, warrants to the final
purchaser of a Torqeedo DEEP BLUE system that the remaining capacity of DEEP BLUE
high voltage batteries will still be at least 80 % of the original capacity 9 years after com-
missioning, provided that the following basic conditions will be met.
Like all batteries, DEEP BLUE batteries age with time due to temperature effects
(calendrical aging) as well as through use of the battery, including charging and dischar-
ging (cyclical aging). Prerequisite to 9 year capacity warranty of DEEP BLUE batteries is
that combinations of use intensity and battery temperature specified in the chart below
arenotexceeded.
Error Check / Remedy
Very poor motor power • OnmainscreenofdisplaycheckwhetherSlowmodefornavigationinharbours
is activated. For enabling and disabling of Slow mode, throttle must be in neutral
position.
No function of charger • CheckondisplaywhetherchargerissetonON.SetonONifnecessary.
• Incaseoflongcableconnectionbetweensocketandcharger,avoltagedropmay
occur which prevents batteries from being charged. Try to use a shorter cable for
charging, if possible.
• CheckthatkeyswitchofDEEPBLUEsystemhasbeensettoOFFpositionandthat
emergency stop switch is engaged.
• Checkwhetherfuseshaveturnedoffpowerfromsocket.Resetfusesandscale
down charger power as outlined in chapter 4.4.
Increased noise and
vibration in Deep Blue
system
• ContactanauthorizedTorqeedoservicepartner.
When starting, display
displays combination
from E 208, E 210 and
E 138
• Checkemergencyswitchforcorrectseatandtitifnecessary.
If indicated on error messages „Insulation error“, insulation of high
voltage system is damaged. The system remains operable, but must
immediately be checked by Torqeedo service staff. Thanks to connected
DEEP BLUE safety systems, two insulation faults must coincide at the
same time to give rise to risk of injury. However, after an insulation er-
ror has been displayed, as a precautionary measure, avoid any contact
to metal parts as far as possible.

Other manuals for Torqeedo Deep Blue

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Torqeedo Deep Blue and is the answer not in the manual?

Torqeedo Deep Blue Specifications

General IconGeneral
BrandTorqeedo
ModelDeep Blue
CategoryOutboard Motor
LanguageEnglish

Related product manuals