3PrinterOperation
Thischapterprovidesinformationaboutprinteroperation.
3.1MediaSensorCalibration
Youwillwanttheprintertoworkproperlybeforestartingyourprintjobs.Todothis,
you need to calibrate the media sensor. Toshi b a B‐FV4T provides transmissive and
reflectivesensorcalibration.Takethefollowingstepstousethem.
1. Make sure the media is properly loaded, the printermodule is closed, and the
printer’spowerswitchissettotheOFFposition.
2. PressandholdtheFEEDbutton,andturnontheprinter.
3. Bothstatuslightswilllightupsolidorangeforafewseconds.Next,theyturnto
greenshortly,andthenturntoothercolors.Dooneofthefollowingtoselectthe
sensor:
Ifyouwanttocalibratethetransmissivesensor,whenLED1turnstogreenand
LED2turnstored,releasetheFEEDbuttonimmediately.
Ifyouwanttocalibr atethereflectivesensor,whenLED1turnstogreenandLED
2turnstoorange,releasetheFEEDbuttonimmediately.
4. PresstheFEEDbutton.Theprinterwillfeed3‐4labelsoutandstop.