Chapter 1 Before turn on the Power
Computer module C3PU35 User’s Manual
8
Specification
ITEM
PS791S PS735
Status
indicator
POWER (5V output, green)
BATT (Battery, green)
FAN (FAN stopped, red)
Å
RUN Rely Dry A contact (240Vac/24Vdc-0.2AMAX.)
Å
Cooling fan Applicable fan:FA714
Externally mounted (Cooling by blowing from
the lower part)
Å
FAN stop
detection
input (ALM)
1 contact input (12Vdc-10mA supplied)
Å
Shut-down
switch
Shut-down operation is carried out when switch
is set to OFF.
---
Battery
Applicable lithium battery: Available by
mounting the battery in ER-6 CF.
Å
Battery voltage
indication
BATT ON in normal operation, OFF at 2.7 to
2.9Vdc
Å
Test terminal 3 terminals (5V, 3.3V, 0V)
Å
Additional functions
Adjustment
knob
3 knobs (for 5Vdc, 3.3Vdc, Reset detection
voltage adjustments)
Å
Weight 1.5kg or less
External
dimensions
250H x 60W x 110D
250H x 60W x 130D
Materials Rear side mounting part:Aluminum
Center part:Iron
Front part:ABS resin (UL94-V0)
Å
Housing
Line terminal
unit
11 terminals -M3.5 screw (detachable)
Å
Important
• Do not connect to the same electrical outlet with equipment that has high power
consumption or emits noise, such as air conditioner or copier.
• Use of uninterruptible power supply is recommended in order to prevent loss of
power and to protect the content of the hard disk in the event of a power failure.
The content of the hard disk is not guaranteed if power is lost due to power failure.

Table of Contents