Computer module C3PU35 User’s Manual
24
3.1.3 Power Off with Windows
If a power supply is turned off without shutdown of Windows, the data in a hard disk is
destroyed and it may be unable to reboot.
Model 3000 is supporting the automatic shutdown of Windows, and the power supply
off-sequence. If the power supply module PS791S is used, the shutdown of Windows
can be performed without carrying out operation of a mouse and a keyboard.
Important
• In turning off the power supply of module, turn off the power supply switch of
PS791S.
• Don't turn off AC power supply until the power supply of module is turned off
automatically.
• The power supply of I/O modules is not turned off, either, until the C3 is shutdown.
Moreover, when two or more C3s are mounted in the unit, a power supply is not
turned off until all C3s are shutdown.