Chapter 4 Maintenance 
 
Computer module C3PU35 User’s Manual
 
30
4.2
 
 Periodic Maintenance 
Check the following items periodically (once every six month is recommended). Also 
check these items when the surrounding condition or environment is changed. 
 
Item  Inspection Description  Action 
Power supply voltage 
(measure at the power supply 
terminal of the module) 
AC85 - 132VAC/170 - 264VAC 
Check for loose power supply 
terminal screws 
Must be secure 
Power supply 
related 
Check for damaged cables  Must not be damaged 
Check that the base unit is 
securely in place 
Must not be loose 
Check that each module is 
securely in place 
Must not be loose 
Installation 
Check for loose connector in 
front of the module and 
damaged cables 
Must not be loose or damaged 
Measure voltage of each I/O 
terminal 
Must be within specification 
Check the input status LED  Must turn ON normally 
Check the output status LED  Must turn ON normally 
Check that the I/O terminal is 
secure 
Must not be loose 
Check that the terminal 
screws are secure and not 
touching each other 
Must not be loose or touching 
each other 
I/O module 
related 
Check for damaged cables  Must not be damaged 
Environment  Check the temperature, 
humidity, vibration, and dust 
Must be within installation 
environment specification 
C3 built-in Litium battery  Should be replaced after 10 years 
by C3 overhaul 
Other battery 
(Power Supply module) 
Should be replaced after two 
years 
Battery related 
Check that the battery 
connector is connected 
securely 
Must be secure 
Cleaning of a filter  Neither garbage nor dust should 
be in the air filter of the front of a 
fan unit 
Installation  The unit and connector must not 
be loose. The cables must not be 
damaged. 
FAN unit 
Fan unit exchange time  Should be replaced after 10 years
 
 WARNING
 
• Do not attempt to disassemble, modify, or repair. 
This can cause electrocution, fire, or injury. 
Contact the Toshiba service desk for repair.