e-STUDIO160/200/250 SCANNER 7 - 28 December 2002 TOSHIBA TEC
Fig. 7-8-31
Fig. 7-8-32
Wire
Wire roller
Wire
Wire
Wire
Timing belt 157
Scanner drive gear
Scanner
drive shaft
Bearing
E-ring
Bearing
E-ring
Wire
064-1
Screw
063-1
16. Remove spring plate securing mirror 3 and re-
move mirror 3.
Notes: 1. Clean the surface of mirror 3 if dirty.
2. For mounting Carriage 2, refer to the Ser-
vice Handbook. (See Chapter 1.8)
[CAUTION]
Never turn the angle adjusting screw of mirror.
Fig. 7-8-30
Spring plate
Spring plate
Mirror 3
Screw
Spring plate
060-3
[I] Scanner drive shaft/wire
1. 1. If an Original Cover (KA-1600PC), ADF
(MR-2012), or the RADF (MR-3011) is attached
to the copier, detach it.
2. If a STP (KK-1600) is attached to the copier,
detach it.
3. Detach the manual pocket.
4. If a Finisher (MJ-1011) is attached to the copier,
detach the finisher plate.
5. Remove scanner assembly.
(See Fig. 7-8-1 to 7-8-6)
6. Remove scanner motor assembly.
(See Fig. 7-8-9 and 7-8-11)
7. Release the lamp cable.
(See Fig. 7-8-19 to 7-8-22)
8. Remove the blind plate.
(See Fig. 7-8-16 and 7-8-17)
9. Remove carriage 1. (See Fig. 7-8-24)
10. Detach wire from carriage 2. (See Fig. 7-8-27)
11. Remove wire roller from scanner frame and
release wire.
12. Detach 2 E-rings and 2 bearings, remove
scanner drive shaft assembly, and remove
timing belt 157.
13. Detach wire from scanner drive shaft assembly.
14. Remove the screw and remove scanner drive
gear.
Note: For winding the wire, refer to the Service
Handbook. (See Chapter 1.8)