6
© 2007 - 2008 TOSHIBA TEC CORPORATION All rights reserved e-STUDIO167/207/237
SCANNER
6 - 15
4) Original size is determined by the combination of the signals output from each detection point.
Combination charts for size determination of A4 series and LT series are as follows.
[A4 Series]
[LT Series]
* When the platen sensor (S2) is OFF;
The followings are determined by output signals from the APS sensors.
- Size (The combination of the signals satisfy any in the above chart)
Size is displayed on the control panel and a specific paper or reproduction ratio is selected.
- Size retention (The combination of the signals do not satisfy the above chart)
The latest original size recognized (or no original state) until new paper size is recognized.
- No original (Output from all the sensors are “H”.)
Reproduction ratio and paper are not selected.
Size change is always observed and detected.
The contact image sensor unit (CIS) stays at the standby position even if the reproduction ratio
changes corresponding to the change of the original size.
* When the platen sensor (S2) is ON;
The latest original size (or no original state) recognized right before the platen sensor (S2) is turned
ON is retained regardless of the status the APS sensor output signals.
Size judgement APS-C APS-R APS-1 APS-2 APS-3
A3 00000
A4 01000
B4 00010
B5 11010
A4-R 00110
A5 11110
B5-R 00111
A5-R 01111
Size judgement APS-C APS-R APS-2 APS-3
LD 0000
LT 0100
LG 0010
LT-R 0110
ST 1110
ST-R 0111
Code Output signal Original
1 H Not available
0 L Available